HP XP P9000 for Business Continuity Manager Software Release Notes

Table 11 Restrictions (continued)
Restrictions#
When using BCM to operate from L-site in a 4x4x4 Multi-Target configuration with Delta Resync, start the business
operation after Cnt Ac-S and Cnt Ac-J copy pairs are formed so the Multi-Target configuration is established.
4
BCM does not support a recovery procedure from failure in 4x4x4 Multi-Target configuration with Delta Resync by
misoperation. In this case, use the following assistance:
If you need to call technical support, make sure to provide as much information about the problem as possible,
including:
5
The circumstances surrounding the error or failure.
The content of any error messages displayed on the host systems.
The content of any error messages displayed on Remote Web Console.
The Remote Web Console configuration information (use the FD Dump Tool).
The service information messages (SIMs), including reference codes and severity levels, displayed by Remote
Web Console.
Do not specify the following values to the DADID of a Disk Configuration Definition, a copy group, or a route list.
Specifying those values may cause the information displayed in Discover HP Storage Arrays panel to become
incorrect.
6
“R”
“CMD”
“I”
“K”
“RC”
Examples that cannot be specified:
“R”
xx.R”
“R.xx
xx.R.xx”
where xx is an arbitrary string of one or more characters.
The YKWATCH command is not available for monitoring a copy pair status transition if the PPRCSUM feature in
DEVSUPxx is enabled in z/OS V1R13 or later. Use the YKEWAIT command to monitor instead.
7
Specification differences from previous versions
This section describes the specification differences between V7.5.0 and V7.6.0 of BCM.
Table 12 Functions, commands, and environment values
VersionNew specification in V7.6.0Specification in V7.5.0Item
7.6.0-00Supported the YKBTSCAN.YKBTSCAN function
7.6.0-00SYSLOG=[YES | CONSOLE
| NO]
SYSLOG=[YES | NOYKSETENV command
7.6.0-00Specify YES, CONSOLE, or
NO.
Specify YES, or NO.SYSLOG environment value
Specification differences from previous versions 11