Table 57 Contents of the Scan Copy Pair Inside Storage System Panel
DescriptionItem
Specify the Device Address Domain ID to which the P-VOL of the PPRC
copy pairs to be scanned belong (required).
PrimaryDevice Address
Domain
Use no more than 28 alphanumeric characters. If the specification
exceeds 8 characters, place a period every 8 characters. Hyphens
cannot be specified.
Specify the Device Address Domain ID of the S-VOL of the PPRC copy
pairs to be scanned belong (required for CA or CAA).
Secondary
Use no more than 28 alphanumeric characters. If the specification
exceeds 8 characters, place a period every 8 characters. Hyphens
cannot be specified.
Specify the Non Gen'ed Device Address Domain ID to which the S-VOL
of the PPRC BC copy pairs to be scanned belong (required when the
S-VOL of the BC copy pair is a Non Gen'ed volume).
BC Pair (S-VOL) Non
Gen'ed
Use no more than 28 alphanumeric characters. If the specification
exceeds 8 characters, place a period every 8 characters. Hyphens
cannot be specified.
Specify a CA copy group name (required only when a Device Address
Domain ID is specified for Secondary).
CA Copy Group ID
Two-digit serial numbers beginning with 00 are assigned in ascending
order to the copy group names specified by this parameter (for
example, 00, 01, 02...). You can specify a maximum of six characters
for a copy group name. Do not use hyphens. The initial display is
MYTCS.
Specify a TCA copy group name (required only when a Device Address
Domain ID is specified for Secondary).
TCA Copy Group ID
Two-digit serial numbers beginning with 00 are assigned in ascending
order to the copy group names specified by this parameter (for
example, 00, 01, 02...). You can specify a maximum of six characters
for a copy group name. Do not use hyphens. The initial display is
MYTCA.
Specify a BC copy group name.BC Copy Group ID
Two-digit serial numbers in ascending order beginning with 00 are
assigned to the copy group names specified by this parameter
(example: 00, 01, 02 ...). Use no more than 6 characters for the copy
group name. Hyphens cannot be specified. No initial value is
displayed.
Specify the Start and End of the device number range for scanning the
P-VOL of the PPRC copy pair, using hexadecimal numbers in ascending
order (required).
Device Num
NOTE: The device number range cannot be omitted. To scan only a
single volume, specify the same volume for Start and End.
When creating a CA copy group definition file, you can check whether
HyperSwap is enabled for the detected PPRC copy pair.
HS
If the search range contains both volumes for which HyperSwaps are
enabled and volumes for which HyperSwaps are not enabled, by
specifying CHECK, you can prevent PPRC copy pairs, for which
HyperSwaps are enabled, from being defined in the CA copy group
definition file.
If the search range does not contain volumes for which HyperSwap is
enabled, specify NOCHECK.
• CHECK: Acquires the UCB information (UCBHSWAP) of the P-VOLs
of the detected PPRC copy pairs, and checks whether HyperSwaps
90 ISPF panels