HP XP P9000 for Business Continuity Manager Software Reference Guide
Figure 24 Edit Logical Path Definition Panel
Table 37 (page 58) describes the items in the Edit Logical Path Definition panel.
Table 37 Contents of the Edit Logical Path Definition Panel
DescriptionItem
Path set IDPath Set ID
A description of the path setDescription
Type of pathType
• CU: Inter-CU logical path
• DKC: Inter-DKC logical path
Shared attributes for path (modifiable).SHR
• Y— This path has shared attributes.
The path is deleted only if the FORCE parameter is specified when deleting the path.
• N— This path has no shared attributes.
The path is deleted regardless of whether the FORCE parameter is specified when deleting
the path.
Specify an action.AC
s: Displays the Select Storage System panel used to select the site from a list of storage
systems.
When actions are entered in multiple AC columns, each is processed in the order displayed.
Primary storage system serial number (modifiable)S/NPrimary
Primary storage system model (modifiable)Model
Primary interface version (modifiable)IFType
Specify the primary path group ID (path group ID in the forward direction).PathID
Specify this item only for the inter-DKC logical path. If this item is omitted for the inter-DKC
logical path, 00 is assumed.
Primary CU number (modifiable)CU
Primary SSID (modifiable)SSID
Primary CCA (modifiable)CCA
Secondary storage system serial number (modifiable)S/NSecondary
58 ISPF panels