HP XP P9000 for Business Continuity Manager Software Reference Guide

EXIT(return-code) ~ <numeric characters> ((0 to 4095))
Stops BCM Monitor with the specified return code. HP recommends hat you specify a value other
than 0, 4, 8, or 12 because these numbers are already used as BCM Monitor return codes.
REPORT(copy-group-ID[,{SUMMARY|DETAIL|STATS|RPO}[,{CONS|ERROR|STATUS|INFO}]])
Outputs report information for the specified copy group.
{SUMMARY|DETAIL|STATS|RPO}
Specifies the type of report information:
SUMMARY
Outputs summary information about the copy group.
DETAIL
Outputs detailed information about the copy group.
STATS
Outputs operating information for the copy group. This can only be used for the TCA and CAJ
copy types.
RPO
Outputs consistency information for the copy group. This can only be used for the TCA and CAJ
copy types.
{CONS|ERROR|STATUS|INFO}
Specifies the message level of the messages that are to be output as report information. For details
on which messages are output for which message level settings, see “Values that Can Be Specified
for the Message Level and the Messages that Are Output for Each Level” (page 365).
WAITFOR(copy-group-ID,{DUPLEX|SUSPEND|SIMPLEX|SUSPVS|HOLD}[,timeout-value])
Executes the YKEWAIT command for the specified copy group and waits until the status changes
to the copy group status specified in this parameter. Note that if the specified timeout value is
reached before the specified status is obtained or if an invalid status results, the error action is
executed. For details on invalid statuses, see “Invalid Status for Each Value Specifiable in the
GOTO Parameter” (page 204).
{DUPLEX|SUSPEND|SIMPLEX|SUSPVS|HOLD}
Specifies the status of the copy group that is specified in the GOTO parameter of the YKEWAIT
command. After all copy pairs in the copy group have changed to the specified status, the
processing terminates normally. For details on this value, see the description of the GOTO parameter
in “YKEWAIT Command” (page 202).
timeout-value ~ <numeric characters> ((0 to 9999))
Specifies (in minutes) the timeout value that is specified in the TIMEOUT parameter in the YKEWAIT
command. If you omit this value, the value specified for the WAITTIMEOUT parameter in the
YKMONOPT file is used. For details on this value, see the description of the TIMEOUT parameter
in “YKEWAIT Command” (page 202).
RESYNC(copy-group-ID,command-wait-time[,'command-parameter'])
Executes the YKRESYNC command with the specified command parameter on the specified copy
group after the specified command wait time elapses.
command-wait-time ~ <numeric character>((0 to 9999))
Specifies in minutes the wait time before the YKRESYNC command is executed.
command-parameter ~ <up to 256 characters of command parameter string>
374 BCM Monitor Parameter Files