HP XP P9000 for Business Continuity Manager Software Reference Guide
Information to be set
This parameter file sets the option information required for starting BCM Monitor.
Parameters
CYCLETIME=cycle-time ~ <numeric character>((10 to 999999))<<300>>
Specifies the cycle time in seconds for monitoring the copy group status.
The following figure shows the concept of the copy group status monitoring cycle.
If the specified value is from 0 to 9, 10 seconds is used for CYCLETIME.
WAITTIMEOUT=timeout-value ~ <numeric characters>((0 to 9999))<<180>>
Specifies the default timeout value in minutes to use when no timeout value is specified for the
YKEWAIT command in the ACTION=WAITFOR parameter in the YKMONCG file. This value is also
used as the timeout value for the YKEWAIT command, which is issued when the CGSTARTUPSTATUS
parameter is specified in the YKMONCG file.
MSGLEVEL=SYSTSPRT-message-level,console-message-level ~ <<INFO,CONS>>
Specifies the message level of the messages to be output to SYSTSPRT and the console.
“Values that Can Be Specified for the Message Level and the Messages that Are Output for Each
Level” (page 365) lists the values that can be specified for the message level and the messages that
are output for each level.
Table 161 Values that Can Be Specified for the Message Level and the Messages that Are Output
for Each Level
Messages that are outputMessage level
YK80nnZ, YK81nnZCONS
YK80nnZ, YK81nnZ, YK82nnZERROR
YK80nnZ, YK81nnZ, YK82nnZ, YK83nnnZSTATUS
YK80nnZ, YK81nnZ, YK82nnZ, YK83nnZ, YK84nnZINFO
The messages that are output are as follows:
• YK80nnZ: These are messages that are output regardless of the specified message level.
However, note that some messages might be output only to SYSTSPRT or the console.
• YK81nnZ: These are messages with the highest level of importance.
• YK82nnZ: These are error messages.
• YK83nnZ: These are messages that report statuses.
• YK84nnZ: These are information messages.
ONACTIONERROR={SKIPONLY|STOP|EXIT(return-code)} ~ <<SKIPONLY>>
YKMONOPT File 365