HP XP P9000 for Business Continuity Manager Software Reference Guide
Table 150 Device Information Structure (continued)
DescriptionREXX variables
Physical DKC serial numberPhysicalSerialNum
13
Logical DKC numberLDKCNum
13
1
When the information is acquired, Valid is stored.
2
For Non Gen'ed volumes or remote storage system volumes, information cannot be obtained for
the following storage system models:
• XP12000/XP10000 Disk Array
• XP24000/XP20000 Disk Array
• XP P9500 Disk Array
3
Information can be acquired for the following models:
• HP XP12000/XP10000 Disk Array
• HP XP24000/XP20000 Disk Array
• HP XP P9500 Disk Array
4
When the emulation type of the journal volume is OPEN-V, NORMAL is displayed.
5
Information can be acquired for CA.
6
Information can be acquired for TCA.
7
This value is invalid for a PPRC copy pair.
8
Information can be acquired for CA with consistency group ID specified.
9
Displayed in GMT.
10
Information can be acquired for P-VOL when the status for the Continuous Access Journal copy
pair is PENDING or DUPLEX.
11
When the copy type is CAJ, and the following models supports the relevant attribute settings,
information is displayed.
• HP XP12000/XP10000 Disk Array
• HP XP24000/XP20000 Disk Array
• HP XP P9500 Disk Array
When information could not be acquired, the value becomes null.
12
When the copy type is CAJ, and the following model supports the relevant attribute settings,
information is displayed:
• VSP (XP P9500)
When information cannot be acquired, the value becomes null.
13
Information can be acquired for HP XP24000/XP20000 Disk Array and XP P9500 Disk Array.
Path Set Structure
Table 151 (page 348) shows the path set structure. Prefixes for the name of the path set structure
is stem-name-specified-in-STEM-parameter and PATH.
NOTE: You can use the YKDROP command to drop the REXX variables in any path set structure
that was loaded by using the YKLOAD command.
Each variable is preceded by a period (.).
About REXX Variable Structures 347