HP XP P9000 for Business Continuity Manager Software Reference Guide

Table 150 Device Information Structure (continued)
DescriptionREXX variables
Number of physical paths in inter-CU logical path
(0 to 8)
0P2S
Status of physical pathStatusn
NO PATH
ESTABLISHED
INIT FAILED
TIME OUT
NO RESOURCES AT PRI
NO RESOURCES AT SEC
SERIAL# MISMATCH
CONFIG ERROR
Initiator port number (for ESCON, link address)Pri.Port
Target port number (for ESCON, link address)Sec.Port
Secondary CU numberSec.CUNum
Existence of inter-DKC path information (Valid)Info
1
DKC
Model of secondary storage systemModelSec
7700E (XP256)
9900 (XP512/XP48)
9900V (XP1024/XP128)
USP (XP12000/XP10000)
USPV (XP24000/XP20000)
VSP (XP P9500)
Serial number of secondary storage systemSerialnum
Number of path group IDs established from the
storage system to which this device belongs to
the storage system of Sec.SerialNum (0 to 64)
0
Path group IDPATHIDn
Number of physical paths (0–8) in the inter-disk
controller logical path with the corresponding
path group ID
0
Status of physical pathStatusn
NO PATH
ESTABLISHED
INIT FAILED
TIME OUT
NO RESOURCES AT PRI
NO RESOURCES AT SEC
SERIAL# MISMATCH
CONFIG ERROR
Initiator port numberPri.Port
Target port numberSec.Port
Existence of PSN information (Valid)Info
1
PSN
346 Data Objects