Table 150 Device Information Structure (continued)
DescriptionREXX variables
Number of physical paths in inter-CU logical path
(0 to 8)
0P2S
Status of physical pathStatusn
• NO PATH
• ESTABLISHED
• INIT FAILED
• TIME OUT
• NO RESOURCES AT PRI
• NO RESOURCES AT SEC
• SERIAL# MISMATCH
• CONFIG ERROR
Initiator port number (for ESCON, link address)Pri.Port
Target port number (for ESCON, link address)Sec.Port
Secondary CU numberSec.CUNum
Existence of inter-DKC path information (Valid)Info
1
DKC
Model of secondary storage systemModelSec
• 7700E (XP256)
• 9900 (XP512/XP48)
• 9900V (XP1024/XP128)
• USP (XP12000/XP10000)
• USPV (XP24000/XP20000)
• VSP (XP P9500)
Serial number of secondary storage systemSerialnum
Number of path group IDs established from the
storage system to which this device belongs to
the storage system of Sec.SerialNum (0 to 64)
0
Path group IDPATHIDn
Number of physical paths (0–8) in the inter-disk
controller logical path with the corresponding
path group ID
0
Status of physical pathStatusn
• NO PATH
• ESTABLISHED
• INIT FAILED
• TIME OUT
• NO RESOURCES AT PRI
• NO RESOURCES AT SEC
• SERIAL# MISMATCH
• CONFIG ERROR
Initiator port numberPri.Port
Target port numberSec.Port
Existence of PSN information (Valid)Info
1
PSN