HP XP P9000 for Business Continuity Manager Software Reference Guide
Table 150 Device Information Structure (continued)
DescriptionREXX variables
(This indicates whether secondary volumes
transitioning to the suspend status can be
accessed or updated.)
• STEADY: Volumes can be accessed or
updated after the copy operation is completed.
• QUICK: Volumes can be accessed or updated
even while the copy operation is in progress.
ATTIME suspend statusStatus
• Notset: The ATTIME suspend time is not set.
• PRESET: The ATTIME suspend time is set, but
suspend has not been performed.
• SUSPEND (TIMESTAMP): Suspend was
performed because the ATTIME suspend time
elapsed.
• SUSPEND (TIMEOUT): Suspend was
performed because a timeout occurred.
• SUSPEND (NOIO): Suspend was performed
because no update journal was detected.
BC copy group statusSIStatus
• WAITING: Suspend processing has not been
started.
• SUSPENDING: Suspend processing is ongoing.
• SUSPEND: Suspend processing ended
normally.
• ERROR: Suspend processing ended
abnormally.
The status of the Cnt Ac-J Z copy group when the
BC copy group is suspended.
URStatus
• DUPLEX: When suspend was performed, all
Cnt Ac-J Z copy pairs were in DUPLEX status.
• UNEXPECTED: When a suspend was
performed, some Cnt Ac-J Z copy pairs were
not in DUPLEX status.
Error code (hexadecimal number: 0000-FFFF)ErrorCode
ATTIME suspend information (yyyymmdd
hh:mm:ss.nnnnnn)
Time
9
Timeout value since the command is issued
(minutes)
Tout
Timeout value since the ATTIME suspend time
(minutes)
Tout2
Time remaining until timeout (minutes)Trem
Consistency time for the Cnt Ac-J Z copy group
at suspension (yyyymmdd hh:mm:ss.nnnnnn)
CTTime
9
Existence of copy pair information (Valid)Info
1
UR
Number of Cnt Ac-J Z copy pairs0
About REXX Variable Structures 343