HP XP P9000 for Business Continuity Manager Software Reference Guide
Table 150 Device Information Structure (continued)
DescriptionREXX variables
SSID of P-VOLSSIDPri
Storage system serial number of P-VOLSerialnum
CU number of P-VOLCUNum
CCA of P-VOLCCA
SSID of S-VOLSSIDSec
Storage system serial number of S-VOLSerialnum
CU number of S-VOLCUNum
CCA of S-VOLCCA
Consistency group IDIDCT
Existence of ATTIME suspend information (Valid)Info
1
AT
Generation IDGenID
ATTIME suspend time (yyyymmdd
hh:mm:ss.nnnnnn)
Time
9
Timeout value (minutes)Tout
ATTIME statusStatus
• Notset: The ATTIME suspend time is not set.
• PRESET: The ATTIME suspend time is set, but
suspend has not been performed.
• SUSPEND (TIMESTAMP): Suspend was
performed because the ATTIME suspend time
elapsed.
• SUSPEND (TIMEOUT): Suspend was
performed because a timeout occurred.
Number of copy pairs in the C/T groupPairCt
Number of suspended copy pairsSuspendOpCt
Number of suspending copy pairsTransCt
Number of failure suspended copy pairsSuspendErCt
Time remaining until timeout (minutes)Trem
Number of copy pairs made by full copyPendingCt
Number of Duplex copy pairs in the C/T group
to which the specified device belongs
DuplexCt
Number of Resync copy pairs in the C/T group
to which the specified device belongs
ResyncCt
Existence of CAJ ATTIME suspend information
(Valid)
Info
1
AT_UR
Restore journal group IDR_JNL
Generation ID (hexadecimal number: 00-FF)GenID
Suspend mode used by the CAJ ATTIME suspend
function.
SplitMode
342 Data Objects