HP XP P9000 for Business Continuity Manager Software Reference Guide
NOTE: When entering a DAD ID, remember the following:
• Specify the same DAD ID for volumes that can be directly accessed. Business Continuity
Manager assumes that volumes with the same DAD ID as the one specified for the Set Defaults
panel can be directly accessed.
• For BC, the same DAD ID must be specified for P-VOL and S-VOL. However, when defining
a Non Gen'ed volume and a Gen'ed volume inside the same storage system as a BC copy
pair, specify the respective values (the DAD ID used during an NG scan and the DAD ID used
during a local scan).
Manage Licenses panel (license management)
The Manage Licenses panel is displayed when 2 Manage Licenses is selected in the Main Menu
panel. In the Manage Licenses panel, you can register licenses or display license information.
The following figure shows the Manage Licenses panel.
Manage Licenses Row 1 to 2 of 2
Command ===> Scroll ===> PAGE
2008/03/11 19:44:14
Enter the license key information below and press ENTER to install.
License Key Dataset Name
or Key Code
License List -----------------------------------------------------------------
PP Name Serial Num Model Type Capacity Expires
Basic 12345 5 Perm. 10 ----------
CAJ 4x4 Extended CTG 12345 5 Perm. 10 ----------
******************************* Bottom of data ********************************
F1=Help F3=Exit F4=Refresh F7=Backward F8=Forward F12=Cancel
Table 12 (page 30) lists and describes the items in the Manage Licenses panel.
Table 12 Contents of the Manage Licenses panel
DescriptionItem
The dataset name of the license key file that has been transferred to MVS.License Key Dataset Name
Key code of the licenseKey Code
License namePP Name
Physical Storage system serial numberSerial Num
Storage system model codeModel
For details about the displayed values, see Help.
License typeType
• Perm: Permanent license.
• Temp: Temporary license.
• Emer: Emergency license.
Licensed capacity (in TB or Unlimited)Capacity(TB)
Unlimited indicates unlimited capacity.
Expiration date of the licenseExpires