HP XP P9000 for Business Continuity Manager Software Reference Guide

SN(storage system-serial-number) ~ <from 5 to 12 alphanumeric characters>
Specify the serial number of the storage system to which the volume obtaining storage system
information belongs.
When this parameter is specified, the route list needs to be loaded before the command is executed.
CU(cu-number) ~ <2-digit hexadecimal number>
Specify the CU number of the volume for obtaining storage system information.
When this parameter is specified, the route list needs to be loaded before the command is executed.
CCA(cca-number) ~ <2-digit hexadecimal number>
Specify the CCA number of the volume for obtaining storage system information.
When this parameter is specified, the route list needs to be loaded before the command is executed.
DEVN(device-number) ~ <4-digit hexadecimal number>
Specify the device number of the volume for obtaining storage system information.
This parameter can only be specified for locally connected devices. It cannot be specified for Non
Gen'ed volumes.
MSG(stem-name-2) ~ <REXX prefix of 64 or fewer characters>
Specify an optional prefix for the name of the message structure used to store the messages to be
generated by this command. You must also include a trailing period character.
The message structure is initialized when the CLI command with the same name as the MSG
parameter is specified.
PATH
Specify this parameter to obtain information on inter-CU or inter-DKC logical paths. If this parameter
is specified, the command obtains information on the inter-DKC logical paths that are established
from storage systems to which the volume specified by the DEVN parameter or the SN, CU, and
CCA parameters belongs. Additionally, the command also obtains information on inter-CU logical
paths established from CUs to which this volume belongs. The obtained information is stored in a
path set structure whose name begins with stem-name-specified-in-STEM-parameterPATH.
SSN(serial-number) ~ <from 5 to 12 alphanumeric characters>
To obtain information on an inter-DKC logical path, specify the serial number of the secondary
storage system for the inter-DKC logical path you want to obtain. You can obtain information on
inter-DKC logical paths whose primary storage system to which the volume specified by the DEVN
parameter or the SN, CU, and CCA parameters belongs, and whose secondary storage system is
one that has the serial number specified by the SSN parameter. If this parameter is omitted, even
if the PATH parameter is specified, the command will only acquire inter-CU logical path information
(without acquiring inter-DKC logical path information).
SMODEL({USP|USPV|VSP})
To obtain information on an inter-DKC logical path, specify the model of the secondary storage
system for the inter-DKC logical path you want to obtain. If this parameter is omitted, USP is
assumed.
USP
Specify this option when the model of the secondary storage system for the inter-DKC logical path
you want to obtain is HP XP12000/XP10000 Disk Array.
228 CLI Commands