HP XP P9000 for Business Continuity Manager Software Reference Guide
The message structure is initialized when the CLI command with the same name as the MSG
parameter is called.
TIMEOUT(timeout-value) ~ <numeric characters> ((100-5000)) <<1000>>
Specify the timeout value in milliseconds. When the time specified with this value has elapsed after
executing the YKFREEZE command, the system automatically resets the SCP status.
You can specify a value up to 5000 milliseconds in increments of 100 milliseconds. If you omit
this parameter, 1000 milliseconds is assumed.
Return Codes
Table 112 (page 210) lists the return codes to be returned when the YKFREEZE command terminates.
Table 112 YKFREEZE Command Return Code List
MeaningReturn Code
The command terminated abnormally, possibly because the user SVC routine has
not been included properly.
-4095 to -4040
The module cannot be loaded. Possible causes are as follows:-3
• The library dataset has not been linked.
• The module is protected by the RACF program control function.
An interruption occurred during execution.-1
The command completed normally.0
32
• I/O errors were encountered.
• A change in an I/O configuration definition was detected.
Invalid or unknown elements are found in the structure.36
An error occurred while a REXX variable was being written.40
Terminating due to processing errors.44
Terminating due to invalid parameters.48
The command terminated abnormally. The user does not have permission to execute
this command.
128
YKH2B Command
Applies to Continuous Access Synchronous for Mainframe with the HyperSwap attribute.
Format
YKH2B
1
PREFIX(prefix)
1
DEVN(device-number-1,device-number-2)
1
DAD(dad-id)
1
CGNAME(name-of-CntAcSZ-copy-group-with-HyperSwap-attribute)
[
1
HS({CHECK|NOCHECK})]
Function
This is a TSO/E command.
This command scans the P-VOLs of PPRC copy pairs within the specified range. It then creates a
copy group definition file by defining copy pairs that consist of the detected P-VOLs and S-VOLs
(CA copy pairs that have the HyperSwap attribute of Business Continuity Manager).
Before executing this command, you must use Business Continuity Manager to create a disk
configuration definition file for the storage system to scan. If the disk configuration definition file
210 CLI Commands