HP XP P9000 for Business Continuity Manager Software Reference Guide
D: Whether you need to load the configuration file depends on the situation.
--: You do not need to load the configuration file.
Command details
This section describes command details. For details about the syntax symbols used in the
explanations, see “Symbols Used in Syntax Explanations” (page 389)
YKBLDCMD Command
Applies to CMD.
Format
YKBLDCMD
{
1
SN(storage system-serial-number)|
1
SN(storage-system-serial-number)
1
CU(CU-number)
1
CCA(CCA-number)
1
APID(APID)|
1
DEVN(device-number)
1
APID(APID)}
1
MSG(stem-name-1)
Function
This command is a TSO/E command called from REXX scripts.
The command registers, into the storage system, the command device that was specified in the
route list that was loaded before this command was executed.
Parameters
SN(storage system-serial-number) ~ <from 5 to 12 alphanumeric characters>
When you register the command devices for a storage system in the route list, specify the storage
system serial number.
SN(storage-system-serial-number)CU(CU-number)CCA(CCA-number)APID(APID)
When you specify and register a command device in the route list, specify the serial number of
the storage system, CU number, CCA number, and APID for the command device.
SN(storage-system-serial-number) ~ <from 5 to 12 alphanumeric characters>
Specify the storage system serial number.
CU(CU-number) ~ <two-digit hexadecimal number>
Specify the CU number.
CCA(CCA-number) ~ <two-digit hexadecimal number>
Specify the CCA number.
APID(APID) ~ <four-digit hexadecimal number>
Specify the APID.
DEVN(device-number)APID(APID)
When you specify and register a command device, specify the device number and the APID of
the command device.
Only when you specify this parameter do you not have to load the route list. The DEVN parameter
cannot be specified for remotely connected storage systems.
DEVN(device-number) ~ <four-digit hexadecimal number>
Specify the device number.
Command details 183