HP XP P9000 for Business Continuity Manager Software Reference Guide

Table 75 Contents of the Volume Query Information (BC) panel (continued)
DescriptionItem
ERROR(0002): Since a storage
system-derived error occurred, suspend
processing for the BC copy pair was
abnormally terminated. Contact the storage
administrator.
N/A: One of the following conditions
applies:
The CAJ ATTIME suspend function is not
used.
Suspension of the BC copy pair has not
started.
The BC copy pair has been suspended.
Consistency group IDC/T ID
Write-protect for the S-VOL
4
PROT MODE
PROTECT: Update of the S-VOL is
prohibited after the copy pair is suspended
(YKSUSPND command is executed).
PERMIT: Update of the S-VOL is allowed
after the copy pair is suspended
(YKSUSPND command is executed).
Pace of copying
4, 1
COPY PACE
NORMAL: The speed of the copy operation
improves. However, update I/O load on
P-VOL is high, and this might affect the I/O
performance of the host.
SLOW: Slows the speed of the copy
operation so that the effect of the copy
operation on the I/O performance of the
host is minimal.
Generation IDGEN ID
The following information is displayed if there
are any other copy pairs apart from the one
specified in the Copy Group Pair Status panel:
TypePrimary/SecondaryOther CopyPair
Information
5
Copy type
Indication of whether it is information on
the P-VOL or S-VOL (Pri or Sec)
Consistency group ID and subconsistency
group ID
C/T ID
Manage Copy Groups Panel (Copy Group Operation) 131