HP XP P9000 for Business Continuity Manager Software Messages

Table 1 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YK80x) (continued)
Explanation and recommended actionsMessage textMessage ID
40: The prefix specified in the YKMONCG file is being used
by the Business Continuity Manager agent.
44: An attempt to initialize the subtask failed.
The task terminated abnormally during startup of BCM Monitor.
BCM Monitor will stop.
Task(task-ID) abended:
completion-code.
YK8009E CON
task-ID
Name for identifying the task
completion-code
System completion code
The load module identified by load-module-name cannot be found.
BCM Monitor will stop.
Module not found:
load-module-name.
YK8010E CON
Check whether the load module has been properly installed.
The STGADMIN.YKA.BCM.YKQUERY profile or the
STGADMIN.YKA.BCM.COMMANDS profile is not defined in the
FACILITY class of RACF.
The profile is not defined in
the facility class of RACF:
xxxxxxxx.
YK8011E CON
Review the RACF settings, and then restart BCM Monitor.
xxxxxxxx
Maintenance information
The specified prefix prefix-name is being used by another program.The specified prefix is being
used by another program:
prefix-name.
YK8012E CON
Review the YKMONCG file.
BCM Monitor terminated abnormally.BCM Monitor abended.YK8013E CON
If you cannot determine the cause of this problem, obtain an ABEND
dump in SYSABEND dump format, and then make a request to
technical support to investigate the problem.
BCM Monitor accepted the MODIFY command-name command.MODIFY command
accepted: command-name.
YK8014I CON
BCM Monitor accepted the STOP command.STOP command accepted.YK8015I CON
There is an error in the command syntax.Command syntax error.YK8016E CON
Make sure that the entered command is valid.
There is an error in the command-name command.Invalid command:
command-name.
YK8017E CON
Make sure that the entered command is valid.
There is an error in an operand of the command-name command.Operand is incorrect:
command-name.
YK8018E CON
Correct the operand, and then re-enter the command.
An attempt to execute the command identified by command-name
failed because the number of commands waiting to be executed
has reached the upper limit.
The number of commands of
execution waiting exceed
the upper limit:
command-name.
YK8019E CON
Wait until all the waiting commands are finished executing, and
then re-execute the command.
Information is displayed for the command waiting to be executed.nn:
command-name[parameter].
YK8020I CON
nn
Number assigned to the waiting command
List of messages 9