HP XP P9000 for Business Continuity Manager Software Messages
Table 19 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKS0x) (continued)
Explanation and recommended actionsMessage textMessage ID
configuration file, see the HP XP P9000 for Business
Continuity Manager Software Reference Guide.
• UNAVAILABLE DATASET
The configuration file is being used. Check the usage
of the configuration file.
XX displays the file attribute value that caused the error
and YY displays the correct file attribute value.
file
Name of the configuration file where
the error was detected
The prefix of the REXX variable name specified in the
STEM parameter does not comply with the copy group
Specified STEM() is not
CopyGroup object.
YKS098E MSG SC=36
RC=36
structure described in the HP XP P9000 for Business
Continuity Manager Software Reference Guide.
YKSTORE command processing has completed.YKSTORE Processing Complete.YKS099I MSG TSO
SC=max-severity
RC=max-value
This message is always displayed.
max-severity
Maximum value among the output
severity codes
max-value
Maximum value among the output
return codes
Table 20 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKS2x)
Explanation and recommended actionsMessage textMessage ID
The YKSTORE REXX program can only be invoked via the
YKSTORE assembler REXX subroutine. This message
Invoke YKSTORE REXX Script via
YKSTORE Assembler subroutine.
YKS203E TSO RC=52
indicates the most likely cause of the error indicated in
the previous YKS203E message.
An attempt to acquire the variable value of the Message
structure failed with the result value identified by result.
The MSG(stem) value cannot be
acquired in the caller's
YKS203E TSO RC=52
This implies that the YKSTORE REXX subroutine has notenvironment. (YKVGET result =
result)
properly been invoked or that Business Continuity
Manager has not properly been installed.
stem
Stem name assigned to the MSG
parameter
The value value of the variable identified by name is
invalid.
The value value of the variable
name is an invalid format.
YKS250E MSG SC=36
RC=36
An attempt to output record to a dataset failed because
record was too long.
Too long record: record.YKS260E MSG SC=44
RC=44
Correct the variable setting so that the length of record
becomes 256 characters or shorter.
Creation of the configuration file is stopped because an
error occurred during the creation of the configuration
Failed to operation
configuration file. (name
=dataset-name, dsstate)
YKS270E MSG SC=44
RC=44
file. See the information output in the message to review
List of messages 89