HP XP P9000 for Business Continuity Manager Software Messages

Table 1 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YK80x) (continued)
Explanation and recommended actionsMessage textMessage ID
YKBTSCAN. count Number of scanned devicesCount: countRC=0
The number of HP storage-system devices scannedHP storage systemsYK7032I PRT
by executing YKBTSCAN. count Number of scanned HP
storage-system devices
Devices Found: countRC=0
As a result of a scan, information acquisition wasThe specified devices that doYK7033I PRT
skipped for the devices on which no I/O paths were available.
count Number of devices for which information acquisition was
skipped
not have any available I/O
paths were skipped: count
RC=4
YKBTSCAN terminated with the return code nnnn. This message is
always displayed to indicate the return code. nnnn Maximum value
among the output return codes
YKBTSCAN return
code=nnnn
YK7099I PRT
BCM Monitor has started.BCM Monitor started.
(v.r.m-nn)
YK8001I CON
v.r.m-nn
Version and revision number
BCM Monitor has stopped.BCM Monitor terminated.YK8002I CON
BCM Monitor set the monitoring status of all copy groups to
INACTIVE.
time BCM Monitor stopped
monitoring Copy Groups.
YK8003I PRT CON
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
The copy progress percentage for the copy group identified by
cgid is decreasing.
time Synchronization
percentage decreased,
Copy Group: cgid.
YKJ213E TSO
YK8007I PRT CON
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
cgid
Copy group ID
An attempt to start BCM Monitor failed because of the reason
indicated in a preceding message that was output to either the
console or dd SYSTSPRT.
BCM Monitor initialization
failed: termination-code.
YK8008E CON
Contact the center administrator. If you are the center administrator,
take action that is appropriate to the previously output message,
and then restart BCM Monitor.
termination-code (decimal number)
04: An attempt was made to start BCM Monitor without using
IKJEFT01.
20: An attempt to analyze the YKMONOPT file failed.
24: An attempt to analyze the YKMONCG file failed.
32: An error occurred while loading the process module.
36: No profile is defined in the FACILITY class of RACF.
8 Messages