HP XP P9000 for Business Continuity Manager Software Messages

Table 8 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKG2x) (continued)
Explanation and recommended actionsMessage textMessage ID
Hitachi TrueCopy™ for Mainframe, Hitachi TrueCopy™
Asynchronous for Mainframe, HP Storage Business Copy for
copy-type Copy Group:
dd-name: rec#
Mainframe, or HP Storage Continuous Access Synchronous for
Mainframe.
copy-type
Copy type
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
No volume exists in the range of the Number-Of-Pairs repetitions.The value specified for
Number-of-Pairs exceeds the
YKJ210E TSO
RC=32
Number-Of-Pairs
Number of pair repetitions
range in which volumes
exist: Number-Of-Pairs:
dd-name: rec#
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
A copy pair, which has a P-VOL storage system serial number and
an S-VOL storage system serial number that do not match, was
found in a copy group of copy type BC Z.
PVOL & SVOL of Hitachi
ShadowImage™ for
Mainframe (BC Z) pair is in
YKJ211E TSO
RC=32
dd-name
DD name of the CSV file where the error was
detected
the different storage system:
dd-name: rec#
rec#
Number of the line in the file identified by
dd-name where the error was detected
The combination of the copy groups is one of the following:A specific combination of a
storage system serial number
YKJ212E TSO
RC=32
The serial numbers of the primary site storage systems are the same;
the serial numbers of the secondary site storage systems are
different; and copy pairs with an equal C/T group ID exist.
and a C/T group ID is used
for multiple CAJ Copy
Groups: dd-name: rec#
The serial numbers of the primary site storage systems are different;
the serial numbers of the secondary site storage systems are the
same; and copy pairs with an equal sub C/T group ID exist.
If the copy type is Cnt Ac-J Z, these combinations are not supported.
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
The volume specified as the S-VOL is also specified as the S-VOL
for other copy pairs. The same volume cannot be specified as the
S-VOL for multiple copy pairs.
Secondary volume is already
specified in another copy
pair as a secondary device:
dd-name: rec#
YKJ213E TSO
RC=32
dd-name
54 Messages