HP XP P9000 for Business Continuity Manager Software Messages
Table 8 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKG2x) (continued)
Explanation and recommended actionsMessage textMessage ID
No S-VOL is specified in the pair information CSV file.Secondary volume is not
specified in Pair information
CSV file: dd-name: rec#
YKJ205E TSO
RC=32
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
The specified volume does not exist in the disk configuration
definition file.
The specified volume does
not exist in the disk
YKJ206E TSO
RC=32
dd-name
DD name of the CSV file where the error was
detected
configuration definition file:
dd-name: rec#: device
rec#
Number of the line in the file identified by
dd-name where the error was detected
device
One of the following is displayed. If both are
specified, the device number is displayed.
• Device number
• Storage system serial number, CU number,
and command control address number
The display format is
storage-system-serial-number:CU-number:CCA-number.
The P-VOL specified with the device number differs from the P-VOL
specified with the storage system serial number, CU number, and
command control address number.
Inconsistencies exist among
the values used to specify
the primary volume:
dd-name: rec#
YKJ207W TSO
RC=8
Although the copy group definition file was created, the settings
therein might contain an error.
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
The S-VOL specified with the device number differs from the S-VOL
specified with the storage system serial number, CU number, and
command control address number.
Inconsistencies exist among
the values used to specify
the secondary volume:
dd-name: rec#
YKJ208W TSO
RC=8
Although the copy group definition file was created, the settings
therein might contain an error.
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
A subconsistency group ID is specified for a copy group of the copy
type identified by copy-type. No subconsistency group ID can be
Subconsistency group ID
cannot be specified for a
YKJ209E TSO
RC=32
specified if the copy type is Hitachi ShadowImage™ for Mainframe,
List of messages 53