HP XP P9000 for Business Continuity Manager Software Messages
Table 8 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKG2x) (continued)
Explanation and recommended actionsMessage textMessage ID
name
Parameter name
The specified prefix is being used by another program.The specified PREFIX is
being used by another
program.
YKJ002E TSO
RC=48
Check the value specified for the prefix.
An error occurred during execution of the YKIMPORT command
or YKEXPORT command.
Error occurred during
execution. Cmd= info
msg= message-text:
message-value:
message-severity
YKJ051E TSO
RC=32
See the error message message-text and resolve the problem. Also
see the additional information indicated by message-value and
message-severity and take appropriate action.
If the acquisition of information denoted by message-text,
message-value, or message-severity fails, FATAL is displayed
instead of the information that should be acquired. The reasons for
FATAL to be displayed include an insufficient region size. Review
the current region size, and then retry executing the command.
If the problem is not resolved, contact technical support for
assistance.
info
Maintenance information
message-text
Error message
message-value
Additional information about the error message
If no additional information is available, a space
is displayed.
message-severity
Additional information about the error message
If no additional information is available, a space
is displayed.
The error messages message-text, message-value, and
message-severity are displayed in the TSO/E terminal. Depending
on the length of the error messages, they might extend over several
lines.
The command identified by cmd has ended with a return code
identified by return-code.
cmd command completed.
RC= return-code
YKJ099I TSO RC=0
cmd
Command name
An error occurred while reading data from or writing data to the
configuration file.
Error occurred during
reading/writing
configuration file: file
YKJ100E TSO
RC=32
file
Name of the configuration file where the error
was detected
No copy pair is defined for the specified copy group. No data
was written in the CSV file.
No copy pair is defined in
specified Copy Group
definition: file
YKJ101I TSO RC=4
file
Name of the specified copy group definition file