HP XP P9000 for Business Continuity Manager Software Messages

Table 7 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKG0x) (continued)
Explanation and recommended actionsMessage textMessage ID
The last character of the STEM parameter is not a period.STEM(stem) does not include
trailing "." character.
YKG005E MSG
SC=48 RC=48
stem
Stem name assigned to the STEM parameter
Nothing or an invalid value is assigned to the PREFIX parameter.Unable to execute without
valid PREFIX() parameter.
YKG006E MSG
SC=48 RC=48
To correct the error, see the CLI command descriptions in the HP
XP P9000 for Business Continuity Manager Software Reference
Guide, and then re-execute the command.
An invalid value is assigned to the internal parameter SN that
indicates the storage system serial number contained in the disk
configuration definition file name.
Unable to execute without
valid SN() parameter.
YKG008E MSG
SC=48 RC=48
Check the disk configuration definition file name.
The system does not recognize the XML element name that exists
on the line with the line number identified by rec# in the file
identified by file.
Unrecognized element
encountered: name
YKG050W MSG
SC=4 RC=4
(file:rec#)
Check the indicated line, and then identify the cause of the problem
by referring to information contained in the XML document type
definitions, in the HP XP P9000 for Business Continuity Manager
Software Reference Guide.
file
Name of the XML file where the error was
detected
rec#
Number of the line in the file identified by file
where the error was detected
XML input analysis detected a syntax error on the line with the line
number identified by rec# in the file identified by file.
End of file encountered in
comment.
YKG051E MSG
SC=36 RC=36
(file:rec#)
Check the indicated line, and then identify the cause of the problem
by referring to information contained in the XML document type
definitions, in the HP XP P9000 for Business Continuity Manager
Software Reference Guide.
file
Name of the XML file where the error was
detected
rec#
Number of the line in the file identified by file
where the error was detected
The system does not recognize the version attribute value of the
XML element that exists on the line with the line number identified
by rec# in the file identified by file.
Unrecognized Version
attribute value: value
YKG053W MSG
SC=4 RC=4
(file:rec#)
Check the indicated line, and then identify the cause of the problem
by referring to information contained in the XML document type
definitions, in the HP XP P9000 for Business Continuity Manager
Software Reference Guide.
file
Name of the XML file where the error was
detected
rec#
List of messages 39