HP XP P9000 for Business Continuity Manager Software Messages
Table 3 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKC0x) (continued)
Explanation and recommended actionsMessage textMessage ID
The value specified in the FROM parameter is not in hexadecimal
format.
Starting FROM() not valid hexYKC008E MSG
SC=48 RC=48
You cannot specify a device number and a volume serial number
at the same time.
Specify DEV# and VOLSER
parm exclusively
YKC009E MSG
SC=48 RC=48
The value specified in the FROM parameter exceeds the value of
the TO parameter.
Starting FROM() exceeds
ending TO()
YKC009E MSG
SC=48 RC=48
The value specified in the FROMVSN parameter exceeds the value
of the TOVSN parameter.
Starting FROMVSN() exceeds
ending TOVSN()
YKC009E MSG
SC=48 RC=48
Access to the REXX variable identified by name failed.REXX failure return
code=nnnn starting with
variable name
YKC010E TSO
RC=40
For details about the return code, see IKJCT441 in the TSO/E
Programming Services.
nnnn
Error code returned upon REXX access
The number of DASD devices scanned by the YKSCAN command.Scanned DASD Device CountYKC031I MSG
SC=0 (count)
count
Number of scanned DASD devices
The number of HP storage systems scanned by the YKSCAN
command.
HP RAID Storage Systems
Found
YKC032I MSG
SC=0 (count)
count
Number of HP storage systems
As a result of the device scan, information acquisition on devices
for which no I/O path is available was skipped.
The specified devices that do
not have any available I/O
paths were skipped.
YKC033I MSG
SC=4 (count)
count
The number of devices skipped when the device
information was acquired
A dynamic change to an I/O configuration definition was detected
during processing of the YKSCAN command. This error might have
A dynamic configuration
change was detected during
YKSCAN command
processing.
YKC034E MSG
SC=32 RC=32
been caused by the volume serial number in the acquired volume
information being different from the one in the actual configuration.
Check the disk configuration definition file after the scan is
complete. If the volume serial number is different from the one in
the actual configuration, re-execute the scan.
The YKSCAN command terminated with the return code nnnn and
the reason code rrrr.
YKSCAN command return
code=nnnn, reason code=rrrr
YKC099I TSO
This message is always displayed to indicate the return code and
the reason code.
nnnn
Maximum among the severity codes returned
during command execution
34 Messages