Table 66 Details of error codes EBxx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
OutputNot outputThe path for the remote
command transfer route for
EBD3
the second site onwards, or
for the command device,
might not be set, or a failure
occurred in the remote
command transfer route.
Make sure that the path and
the command device are set,
available, and have not
failed, and then re-execute the
operation.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the charging
EBD9
limit of CA in the RCU has
been exceeded. Check the
license capacity of this and
all related program products.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the charging
EBDA
limit of CAA in the RCU has
been exceeded. Check the
license capacity of this and
all related program products.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the charging
EBDB
limit of CAJ in the RCU has
been exceeded. Check the
license capacity of this and
all related program products.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the specified
EBE0
S-VOL is part of a delta resync
CAJ copy pair.
Not outputOutputNot outputA delta resync cannot be
executed because none of the
EBE1
S-VOLs of the delta resync
pair are the S-VOLs of the
other CAJ.
Not outputOutputNot outputA delta resync cannot be
executed because the
EBE2
differential bitmap information
is not ready status to delta
resync. To overwrite the
S-VOL of the delta resync pair
with the P-VOL’s data, execute
the YKRESYNC command with
the ALLJNL parameter.
This error may occur because
the CA update data (master
journal of the delta CAJ pair)
and the update data of the
restore journal maintained by
the CAJ pair is inconsistent.
Not outputOutputNot outputA CAJ copy pair cannot be
made or resynchronized
EBE5