Table 65 Details of error codes EAxx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot outputA CAJ copy pair cannot be
dissolved because the R-JNL
EA2C
group is not in the Active or
Stop status.
Not outputOutputNot outputA CAJ copy pair cannot be
suspended because the M-JNL
EA33
group is not in the Active
status.
Not outputOutputNot outputA CAJ copy pair cannot be
suspended because the R-JNL
EA36
group is not in the Active
status.
Not outputOutputNot outputA CAJ copy pair cannot be
dissolved because the specified
EA3A
S-VOL status is being changed
at the moment.
Not outputOutputNot outputA CAJ copy pair
resynchronization, which
EA3B
causes a copy direction
reversal, cannot be made
because the copy pair is in the
TRANS status.
Not outputOutputNot outputA suspension that reverses the
copy direction cannot be
EA3C
performed for the CAJ copy
pair because the specified
S-VOL belongs to the M-JNL
group.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the charging
EA40
limit of the MCU program
product has been exceeded.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the charging
EA41
limit of the RCU program
product has been exceeded.
Not outputOutputNot outputA CAJ copy pair between the
intermediate site and the
EA46
remote site cannot be deleted
or suspended because the
journal group of the CAJ copy
pair between the primary site
and the intermediate site in a
3DC Cascade (CAJxCAJ)
configuration is in the Active
status.
Not outputOutputNot outputThe CAJ copy pair cannot be
suspended because it is a delta
resync pair.
EA4D
Not outputOutputNot outputThe status cannot be changed
from error status to the delta
EA89
resync preparatory status,
because the specified P-VOL is
not in HOLDER status.