Table 62 Details of error codes C3xx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot
output
The condition setting for the
number of the Minimum Path
C321
between the MCU and the RCU
is invalid.
Not outputOutputNot
output
The MCU is a storage system
type that is not supported by CA
or CAA.
C322
Not outputOutputNot
output
The RCU sequence (number,
SSID or CU) is incorrect.
C324
Not outputOutputNot
output
The RCU is not NVS ON.C325
Not outputOutputNot
output
The subsystem level cache of the
RCU is not valid.
C326
Not outputOutputNot
output
A copy pair cannot be made
because the status of the P-VOL
does not permit remote copy.
C327
Not outputOutputNot
output
The track format of the P-VOL
and S-VOL do not match.
C328
Not outputOutputNot
output
The S-VOL is protected by LDEV
security.
C32A
Not outputOutputNot
output
The P-VOL is protected by LDEV
security.
C32B
Not outputOutputNot
output
The S-VOL is protected by LDEV
guard.
C32C
Not outputOutputNot
output
A copy pair cannot be made
because connection with the
specified S-VOL is not supported.
C32E
Not outputOutputNot
output
The condition for the number of
cylinders for CA or CAA
C32F
volumes is incorrect (the number
of cylinders in the P-VOL > the
number of cylinders in the
S-VOL).
Not outputOutputNot
output
The condition for the CA or CAA
volume capacity is incorrect (not
P-VOL=S-VOL).
C330
Not outputOutputNot
output
The device level cache of the
S-VOL is not valid.
C332
Not outputOutputNot
output
The S-VOL is not DFW ON.C333
Not outputOutputNot
output
The S-VOL is a CAA P-VOL.C335
Not outputOutputNot
output
The S-VOL has PIN data.C336
Not outputOutputNot
output
The S-VOL is in the Reserve
status.
C337