HP XP P9000 for Business Continuity Manager Software Messages

Table 61 Details of error codes C2xx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot
output
A copy pair cannot be made
because the charging limit of
C2A0
the MCU program product has
been exceeded.
Not outputOutputNot
output
A copy pair cannot be made
because the charging limit of
C2A3
CA in the MCU has been
exceeded. Check the license
capacity of this and all related
program products.
Not outputOutputNot
output
A copy pair cannot be made
because the charging limit of
C2A4
CAA in the MCU has been
exceeded. Check the license
capacity of this and all related
program products.
Not outputOutputNot
output
A copy pair cannot be made
because the charging limit of
C2A8
the RCU program product has
been exceeded.
Not outputOutputNot
output
A copy pair cannot be created
because the THPz volume
C2B3
specified for the P-VOL is being
expanded.
Not outputOutputNot
output
A copy pair cannot be created
because the pages of the THPz
C2B6
volume specified for the P-VOL
are being released.
Table 62 Details of error codes C3xx
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot
output
A CA/CAA copy pair that is to
be linked with CAJ cannot be
C300
made because the Disaster
Recovery Extended program
product has not been installed
in the MCU.
Not outputOutputNot
output
A CA/CAA copy pair that is to
be linked with CAJ cannot be
C301
made because the Disaster
Recovery Extended program
product has not been installed
in the RCU.
Not outputOutputNot
output
A copy pair cannot be made
because the charging limit of CA
C305
in the RCU has been exceeded.
Check the license capacity of
this and all related program
products.
Not outputOutputNot
output
A copy pair cannot be made
because the charging limit of
C306
CAA in the RCU has been
Details of error codes 225