HP XP P9000 for Business Continuity Manager Software Messages

Table 57 Details of error codes 8Dxx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
specified by the host command
parameter is the S-VOL.
Not outputOutputNot
output
A status cannot be changed
because the status of the specified
8D1B
copy pair does not match the
actual status.
Not outputOutputNot
output
A CA or CAA copy pair cannot
be made or resynchronized.
8D1C
Possible reasons include one or
more of the following:
The P-VOL is a command
device.
The specified serial number of
the primary storage system or
SSID does not match the
storage system serial number
or SSID of the local CU.
The specified P-VOL does not
match the bootup volume.
The C/T group ID is incorrect.
The P-VOL has not been made
in the corresponding C/T
group.
The S-VOL is not in the Reverse
Resync status.
Either C/T group ID or the C/T
group timer type is incorrect.
Not outputOutputA BC copy pair cannot be made
or resynchronized. Possible
8D1D
reasons include one or more of
the following:
The S-VOL is online.
The status of the copy pair
does not allow the status
transition. For details, see error
code 2310.
The P-VOL is online.
The charging limit of the
program product was
exceeded.
The copy pair is in the Pending
status.
The copy pair is not in the Split
status.
The specified C/T group ID is
not registered.
The number of copy pairs in
the specified C/T group ID
exceeds the maximum number.
OutputNot outputThe serial numbers for the primary
and the secondary storage
8D1E
208 Storage system sense byte information