HP XP P9000 for Business Continuity Manager Software Messages
Table 57 Details of error codes 8Dxx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
specified by the host command
parameter is in the NOT READY
status.
Not outputOutputNot outputThe command could not be
executed because the logical
8D12
volume of the specified volume by
the host command parameter is
blocked.
Not outputOutputThe command could not be
executed because the BC, CA, or
8D14
CAA program product is not
installed.
Not outputOutputA BC copy pair cannot be made
or resynchronized. Possible
8D15
reasons include one or more of
the following:
• The status of the copy pair
does not allow the status
transition. For details, see error
code 2310.
• The charging limit of the
program product was
exceeded.
• The copy pair is in the Pending
status.
• The copy pair is not in the Split
status.
• The specified C/T group ID is
not registered.
Not outputOutputA BC copy pair cannot be made
or resynchronized. Possible
8D16
reasons include one or more of
the following:
• The status of the copy pair
does not allow the status
transition. For details, see error
code 2310.
• The charging limit of the
program product was
exceeded.
• The copy pair is in the Pending
status.
• The copy pair is not in the Split
status.
• The specified C/T group ID is
not registered.
Not outputOutputThe command could not be
executed because the BC, CA, or
8D17
CAA program product is not
installed.
Not outputOutputNot
output
The command could not be
executed because the volume
8D1A
Details of error codes 207