HP XP P9000 for Business Continuity Manager Software Messages

Table 55 Details of error codes 50xx 6Exx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
processing error occurred in the
storage system.
Not
output
OutputNot outputThe information of the pool for
THPz that was specified by the
6ECB
pool ID could not be acquired due
to a logical error.
Not
output
OutputNot outputThe tiering setting information and
relocation status of the THP
6ECC
volume could not be acquired
because an internal processing
error occurred in the storage
system.
Not
output
OutputNot outputThe tiering setting information and
relocation status of the volume for
6ECD
THPz could not be acquired due
to a logical error.
Not
output
OutputNot outputThe performance information of
the THP volume could not be
6ECE
acquired because an internal
processing error occurred in the
storage system.
Not
output
OutputNot outputThe performance information of
the volume for THPz could not be
acquired due to a logical error.
6ECF
Table 56 Details of error codes 7Fxx 8Cxx
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
OutputNot outputThe command cannot be executed
because no program product for
copying is installed.
7F86
OutputNot outputThis command is not supported.7FD4
OutputNot
output
OutputNot outputOutputNot
output
A CA or CAA copy pair status
cannot be changed. Possible
8C12
reasons include one or more of
the following:
The specified S-VOL is online.
The specified volume is either
a CA or CAA pair volume, or
the S-VOL of a BC copy pair.
All paths to the RCU are
blocked.
The status of the copy pair is
not possible for the requested
transition (it is possible that it
is already in requested copy
pair status).
The logical volume of the
specified volume is blocked.
204 Storage system sense byte information