HP XP P9000 for Business Continuity Manager Software Messages

Table 50 Details of error codes 37xx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot outputA CAJ copy pair cannot be
created with the HOLD
3753
parameter in a 3DC (CAJxCAJ)
configuration because the delta
resync function is not supported.
Not outputOutputNot outputA CAJ copy pair cannot be
resynchronized. Possible reasons
include both of the following:
3755
The specified S-VOL is
already in use as an S-VOL
in a CAJ copy pair that has
another mirror ID.
Another CAJ copy pair using
the specified S-VOL is not in
the SWAPPING status.
Not outputOutputNot outputA CAJ copy pair cannot be
made with a value other than 0
3756
specified for the path group ID
because the secondary storage
system does not support values
other than 0 for path group IDs.
Table 51 Details of error codes 46xx
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot outputA CAJ copy pair cannot be made.
Possible reasons include one or
both of the following:
4600
The serial number of the
primary storage system in the
parameter does not match the
serial number of the local
storage system.
The SSID for the P-VOL in the
parameter does not match the
SSID of the local storage
system.
The CU number specified in
the parameter is not
supported.
Not outputOutputNot outputA CAJ copy pair cannot be
suspended. Possible reasons
4601
include one or both of the
following:
The SSID for the P-VOL in the
parameter does not match the
SSID of the local storage
system.
The SSID for the S-VOL in the
parameter does not match the
SSID of the local storage
system.
186 Storage system sense byte information