HP XP P9000 for Business Continuity Manager Software Messages
Table 49 Details of error codes 36xx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
group to be registered is different
from the attribute of the EXCTG.
Not outputOutputNot outputRegistration to EXCTG has failed
because the timer type of the
368A
journal group to be registered is
not System.
Not outputOutputNot outputRegistration to EXCTG has failed
because the combination of the
3694
serial number and device on the
specified arbitration command
device is incorrect.
Not outputOutputNot outputRegistration to EXCTG has failed
because the journal group to be
3695
registered is an open-system journal
group.
Table 50 Details of error codes 37xx
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot outputA CAJ copy pair cannot be
resynchronized (with the
3703
PREPARE parameter) because
the journal volume has PIN data.
Not outputOutputNot outputThe CAJ copy pair cannot be
made because the emulation
3704
type for the specified M-JNL
group does not match that of the
R-JNL group.
Not outputOutputNot outputThe command for delta resync
cannot be executed because the
3705
device on the S-VOL does not
support delta resync.
Not outputOutputNot outputA delta resync pair cannot be
made because the command
3706
target volume is the S-VOL of a
CA copy pair and the copy pair
status is not Duplex.
Not outputOutputNot outputA delta resync pair cannot be
executed. The reason might be
one of the following:
3707
• The command target volume
is the P-VOL of a CA copy
pair and the copy pair status
is not Duplex.
• The command target volume
is the S-VOL of a CA copy
pair and the copy pair status
is not SSWS.
Not outputOutputNot outputThe delta resync command
cannot be executed because
3709
there are no CAJ copy pairs with
a mirror ID other than the one
Details of error codes 183