HP XP P9000 for Business Continuity Manager Software Messages
Table 48 Details of error codes 23xx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
DUPLEX status is included in the
C/T group.
• The ATTIME suspend time
cannot be set because the
specified C/T group contains a
copy pair that was created by
using RAID Manager to specify
the BC C/T group ID.
Not outputOutputThe copy pair cannot be dissolved
because the copy pair is in the
SIMPLEX status.
2311
Not outputOutputThe command could not be
executed because the S-VOL of a
BC copy pair is online.
2312
Not outputOutputA BC copy pair cannot be
suspended because the copy pair
is in the Split status.
2313
Not outputOutputA BC copy pair cannot be made
because the copy pair is in the Split
status.
2314
Not outputOutputA BC copy pair status cannot be
changed. The reason might be one
of the following:
231B
• The status of another copy pair
that shares the P-VOL is
SUSPVS.
• There is a Compatible
FlashCopy pair that shares the
P-VOL.
Not outputOutputA BC copy pair cannot be
resynchronized because the P-VOL
is online.
231F
Not outputOutputA BC copy pair cannot be made
because the charging limit of the
program product was exceeded.
232A
Not outputOutputA BC copy pair cannot be made.
The reason might be one of the
following:
2331
• P-VOL is a Reserve volume.
• The volume size of P-VOL differs
from that of S-VOL.
• The shared memory capacity is
insufficient for copy pair
creation.
Not outputOutputA BC copy pair status cannot be
transitioned because the maximum
2332
multiplicity of the copy pairs for the
P-VOL was exceeded.
Not outputOutputA BC copy pair cannot be
suspended or dissolved because
2333
176 Storage system sense byte information