HP XP P9000 for Business Continuity Manager Software Messages

Table 44 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKZ91x) (continued)
Explanation and recommended actionsMessage textMessage ID
jj (hexadecimal number)
Journal group number specified
for the sub C/T group ID for the
Cnt Ac-J Z that links with BC Z.
gg (hexadecimal number)
Generation ID (00-FF)
ATTIME-suspend-time (GMT)
ATTIME suspend time:
YYYYMMDD-HH:MM:SS.NNNNNN
YYYY: Year
MM: Month
DD: Day
HH: Hour
MM: Minute
SS.NNNNNN: Second
Table 45 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKZ41x)
Explanation and recommended actionsMessage textMessage ID
You cannot use the Errorlevel attribute for this storage
system.
Copygroup SUPFnc does not support
CAJ Errorlevel.
YKZ410E MSG SC=36
RC=36
1
In this case, use a device
2
that supports the Errorlevel
attribute for Cnt Ac-J Z. Also, if a scan was not
performed after the storage system microcode was
replaced, perform another scan.
SUPFnc (hexadecimal number)
Value for the version of the
storage system support function
used in the copy group (minimum)
1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
2
The Errorlevel for Cnt Ac-J Z can be used in a
storage system where the version of the storage
system support function is X'12' or higher.
The YKSUSPND command with the ATOPT(CAJ)
parameter specified was executed on a copy group
CAJ parameter is only valid for BC
Z Copy Groups with C/T ID.
YKZ411E MSG SC=36
RC=48
other than an BC Z copy group with the C/T group
ID specified. The ATOPT(CAJ) parameter is only
valid on BC Z copy groups with the C/T group ID
specified.
Re-execute the YKSUSPND command without
specifying the ATOPT parameter, or with the
ATOPT(NORMAL) parameter specified.
The CAJ ATTIME suspend function is not available
for this storage system.
This device SUPFnc does not support
CAJ ATTIME.
YKZ412E MSG SC=36
RC=48
Use a device
1
for which the CAJ ATTIME suspend
function is supported. Also, if scanning was not
performed after the storage system microcode was
replaced, perform another scan.
List of messages 161