HP XP P9000 for Business Continuity Manager Software Messages

Table 44 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKZ91x) (continued)
Explanation and recommended actionsMessage textMessage ID
The journal group number
specified by the C/T group ID
(00-FF)
kk (hexadecimal number)
The journal group number
specified by the sub C/T group
ID (00-FF)
1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
EXCTG cannot be used on a storage system that has
a P-VOL or uses the remote DKC control function.
Primary device IFType does not
support EXCTG.
YKZ406E MSG SC=36
RC=36
1
Use a device
2
that supports EXCTG. Also, if a scan
has not been performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
2
EXCTG is used in a storage system where the first
two digits of the IFType are X'13' or higher.
EXCTG cannot be used on a storage system that has
a S-VOL or uses the remote DKC control function.
Secondary device IFType does not
support EXCTG.
YKZ406E MSG SC=36
RC=36
1
Use a device
2
that supports EXCTG. Also, if a scan
has not been performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
2
EXCTG is used in a storage system where the first
two digits of the IFType are X'13' or higher.
An error occurred while the suspend processing using
the CAJ ATTIME suspend function was being
performed.
An error occurred during suspension
of CAJ ATTIME. (CT ID=ii, R-JNL=jj,
GENID=gg, ATTSTS=aa, SISTS=ss,
YKZ407E MSG SC=24
RC=24
Check the error information, and remove the cause
of the error. If necessary, also check the storage
URSTS=uu, CODE=eeee,
TIME=ATTIME-suspend-time)
system log. After that, use the YKSUSPND command
to cancel the ATTIME suspend time, and then acquire
a backup again. See “Multi-line messages output to
SYSTSPRT (page 165) for details.
ii (hexadecimal number)
consistency group ID for BC Z
(00-7F)
jj (hexadecimal number)
The journal group number
specified for the sub consistency
group ID for the Cnt Ac-J Z that
links with BC Z (00-FF)
gg (hexadecimal number)
List of messages 157