HP XP P9000 for Business Continuity Manager Software Messages
Table 41 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKZ28x) (continued)
Explanation and recommended actionsMessage textMessage ID
To execute one of these commands against a logical
path, correct the configuration file and then execute
the YKLOAD command.
index
Index number of the logical path
without a port element
When the YKQRYPTH command is executed on a
storage system that has not been directly connected
YKQRYPTH command cannot be
executed if the volume on the CU
type path has not been scanned.
YKZ286E MSG SC=36
RC=36 (index)
to the host for the path set of an inter-control unit
logical path, the volume belonging to the originally
established inter-control unit of the inter-control unit
logical path must have been scanned at least once.
Make sure that the volume belonging to the targeted
control unit has been scanned at least once, and the
control unit and command control address defined
for the path set are correct. If the command control
address is not defined for the path set, from the Edit
Logical Path Definition panel, specify the command
control address of the volume scanned in the target
control unit for path control.
index
Index number of the logical path
that cannot be executed
UR_PathID in the copy group structure is either
NULL or invalid. Correct the configuration file, and
then execute the YKLOAD command.
UR_PathID value null or invalid.YKZ287T MSG SC=36
RC=36
1
value
REXX variable value
1
If this message is output while the YKLOAD command
is being executed, the RC is 44.
A path-controlled storage system does not support
path group IDs (path IDs for which values other than
Some of the storage systems to not
support Path Group ID.
YKZ288E MSG SC=36
RC=36
00 are specified). Revise the definition associated
with whether the storage system can use path group
IDs.
1
Also, if a scan was not performed after the storage
system microcode was changed, perform a scan.
1
Path group IDs can be used for storage systems for
which IFType is X'3333' or higher.
Table 42 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKZ29x)
Explanation and recommended actionsMessage textMessage ID
The FROMCU has exceeded the maximum number of
CUs that are supported by storage systems.
FROMCU() exceeds number of CU
that storage systems supported.
YKZ290E MSG SC=48
RC=48
Specify the maximum supported number of CUs or
less.
The log dataset is full.The log dataset is full. (DSN=ddd,
cp=xxx:yyy)
YKZ291I CON SC=0
RC=0
ddd
List of messages 147