Table 41 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKZ28x) (continued)
Explanation and recommended actionsMessage textMessage ID
models (or later) where the first two digits of the
IFType are X'04' or higher.
Cnt Ac-J Z cannot be used on a storage system that
has a P-VOL or uses the remote DKC control function.
Primary device IFType does not
support CAJ.
YKZ282E MSG SC=36
RC=36
1
Use a device
2
that supports Cnt Ac-J Z. Also, if a
scan was not performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
2
The Cnt Ac-J Z is used in a storage system where
the first two digits of the IFType are X'11' or higher.
Cnt Ac-J Z cannot be used on a storage system that
has an S-VOL or uses the remote DKC control
function.
Secondary device IFType does not
support CAJ.
YKZ282E MSG SC=36
RC=36
1
Use a device
2
that supports Cnt Ac-J Z. Also, if a
scan was not performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
2
The Cnt Ac-J Z is used in a storage system where
the first two digits of the IFType are X'11' or higher.
subCTGroupID in the copy group structure is either
NULL or invalid.
subCTGroupID value null or invalid.YKZ283T MSG SC=36
RC=36
1
Correct the configuration file, and then execute the
YKLOAD command.
value
REXX variable value
1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
Cnt Ac-J Z_MirrorID in the copy group structure
is either NULL or invalid.
CAJ value null or invalid.YKZ284T MSG SC=36
RC=36
1
Correct the configuration file, and then execute the
YKLOAD command.
value
REXX variable value
1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
The YKBLDPTH, YKDELPTH, and YKQRYPTH
commands cannot be executed for a logical path
This command cannot be executed
without a port.
YKZ285I MSG SC=0
RC=0 (index)
without a port element both on primary and
secondary direction. Only the YKQRYPTH command
with a RESTRUCT parameter can be executed on a
logical path without a port element.
146 Messages