HP XP P9000 for Business Continuity Manager Software Messages
Table 38 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKZ25x) (continued)
Explanation and recommended actionsMessage textMessage ID
Maintenance information
The command cannot be executed because Business
Continuity Manager is running for another panel or
script.
This product is already executing.YKZ259E MSG SC=48
RC=48
1
1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
Table 39 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKZ26x)
Explanation and recommended actionsMessage textMessage ID
Processing of some volumes was skipped because a
volume that has already reached the target status
exists.
The volume has already reached the
target status.
YKZ260I MSG SC=0
RC=0
No DD statement is specified in YKLOG01 or
YKLOG02.
The YKLOGnn DD statement is not
specified. (cp=xxx:yyy)
YKZ261E MSG CON
SC=0 RC=0
YKLOGnn
YKLOG01 or YKLOG02
xxx (decimal number)
Command code of the command
that was executing when the error
occurred
See the command code
description in the explanation of
the YKZ201E message.
yyy (string)
Maintenance information
An open error occurred in YKLOG01 or YKLOG02.A YKLOGnn open error occurred.
(rc=nnn, cp=xxx:yyy)
YKZ262E MSG CON
SC=0 RC=0
YKLOGnn
YKLOG01 or YKLOG02
nnn (decimal number)
Return code from the OPEN
macro
xxx (decimal number)
Command code of the command
that was executed when the error
occurred
See the command code
description in the explanation of
the YKZ201E message.
yyy (string)
Maintenance information
An I/O error occurred in YKLOG01 or YKLOG02.A YKLOGnn I/O error. (text,
cp=xxx:yyy)
YKZ263E MSG CON
SC=0 RC=0
YKLOGnn
YKLOG01 or YKLOG02
140 Messages