HP XP P9000 for Business Continuity Manager Software Messages

Table 1 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YK80x) (continued)
Explanation and recommended actionsMessage textMessage ID
BCM Monitor set CYCLETIME to the value identified by cycletime.time Set CYCLETIME to :
cycletime.
YK8048I PRT CON
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
BCM Monitor set WAITTIMEOUT to the value identified by timeout.time Set WAITTIMEOUT to :
timeout.
YK8049I PRT CON
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
BCM Monitor set MSGLEVEL to the values identified by lvllog and
lvlcons.
time Set MSGLEVEL to :
MSGLEVEL=lvllog,lvlcons.
YK8050I PRT CON
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
lvllog
Level of messages to be output to SYSTSPRT
lvlcons
Level of messages to be output to the console
BCM Monitor resumed processing.time BCM Monitor resume
monitoring.
YK8054I PRT CON
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
BCM Monitor will go to sleep because the PAUSE action was
executed.
time BCM Monitor will
pause now for sleep-time
minutes.
YK8055I PRT CON
Entering the WAKEUP command resumes copy group monitoring
before the sleep time of sleep-time has elapsed.
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
sleep-time
Sleep duration
BCM Monitor failed to execute an operator command.time Failed to execute
operator command.
YK8056E PRT CON
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
The file dd-name could not be opened.time File Open error :
dd-name.
YK8070E PRT
14 Messages