HP XP P9000 for Business Continuity Manager Software Messages

Table 38 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKZ25x) (continued)
Explanation and recommended actionsMessage textMessage ID
yyy (string)
Maintenance information
pair-index
See the pair index description in
the explanation of the YKE003E
message.
Business Continuity Manager failed to complete the
requested processing.
DASD device
device-number-1(device-number-2)
YKZ252E MSG SC=8
RC=8
This device is skipped and processing continues.
management error, message-text.
(code1 code2, cmd=xxx, pos=yyy)
Check the status of the error device, and fix the
problem in the configuration or execution condition
if any.
device-number-1 (string)
The device that issued I/O
device-number-2 (string)
The device to be manipulated
message-text (string)
Message text
code1 (Hexadecimal number)
Subcommand code
code2 (Hexadecimal number)
Error code
For details about the error codes,
see “Storage system sense byte
information” (page 171).
xxx (decimal number)
Command code of the command
that was executing when the error
occurred
See the command code
description in the explanation of
the YKZ201E message.
yyy (string)
Maintenance information
An I/O error occurred. Processing will continue with
this device skipped.
DASD device
device-number-1(device-number-2)
YKZ253E MSG SC=32
RC=32 (pair-index)
If a sense byte is set, the sense byte is indicated in
the YKZ255E message.
I/O error. (CC=code1 CSW=code2
code3 code4 code5, cmd=xxx,
pos=yyy).
When CC=3:
The corresponding device might not be configured
or connected.
When CC=0 and CSW=xxxxxx0000xxxx (DSB=00,
CSB=00):
The corresponding device might not be configured
or connected.
List of messages 135