HP XP P9000 for Business Continuity Manager Software Messages
Table 1 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YK80x) (continued)
Explanation and recommended actionsMessage textMessage ID
IRXINIT returns the abnormal termination code
in the two trailing bytes of R0 and returns the
reason code for abnormal termination in the two
leading bytes of R0. If the reason code for
abnormal termination is larger than two bytes,
IRXINIT returns only the two trailing bytes for
the reason code for abnormal termination. For
details on the abnormal termination code and
reason code, see the MVS System Codes.
reason-code
For details about the reason code, see the
TSO/E REXX Reference.
The IRXTERM routine returned an error with the return code
identified by return-code. BCM Monitor will stop.
IRXTERM module error:
code=return-code,
R0=abnormal-termination-code-and-
YK8027E CON
Check the return code.
reason-code-for-
abnormal-termination.
return-code
For details about the return code, see the TSO/E
REXX Reference.
abnormal-termination-code-and-
reason-code-for-abnormal-termination
R0 includes the abnormal termination code and
the reason code for abnormal termination.
IRXTERM returns the abnormal termination code
in the two trailing bytes of R0 and returns the
reason code for abnormal termination in the two
leading bytes of R0. If the reason code for
abnormal termination is larger than two bytes,
IRXTERM returns only the two trailing bytes of
the reason code for abnormal termination. For
details about the abnormal termination code and
reason code, see the MVS System Codes.
The main task or subtask terminated abnormally during BCM
Monitor processing. If the task cannot be recovered, BCM Monitor
will stop.
BCM Monitor function
abend: code=Sxxx Uxxxx
abended-module=module-name
C-Date=module-creation-date
YK8028E CON
Contact the center administrator.
base=bbbbbbbb disp=dddd Sxxx (hexadecimal number)
[calling-module=module-name
C-Date=y'y'.m'm'.d'd'
System completion code when the task
terminated abnormally
base=bbbbbbbb
disp=dddd]
Uxxxx (decimal number)
User completion code when the task terminated
abnormally
PSW=pppppppp pppppppp
ILC=ll INTC=xx
Registers at time of failure
module-name
GR 00-03
contents-of-register-0
Section name of the BCM Monitor module or
load module name.
contents-of-register-1
If the module cannot be identified, UNKNOWN is
displayed. In this case, the values of
y'y'.m'm'.d'd' and bbbbbbbb are invalid.
contents-of-register-2
contents-of-register-3
GR 04-07
contents-of-register-4
module-creation-date
contents-of-register-5
List of messages 11