HP XP P9000 Continuous Access Synchronous for Mainframe Systems User Guide
DescriptionError code
(SSB2)
The add pair operation is rejected because the number of active paths is less than the dedicated number of
minimum paths.
C378
There are fewer paths than the required minimum following a path failure or because an invalid path was
specified.
C379
An internal error occurred.C37A
The S-VOL is not available.C37B
The storage system level cache is not valid in the RCU.C37C
The NVS is not ON in the RCU.C37D
The S-VOL cache is unavailable.C37E
The S-VOL DFW is disabled.C37F
The main system cache is in transition to blockage on one side.C380
The main system cache is in the process of being restored.C381
The main system cache is either in transition to blockage on one side or in the process of being restored on
one side.
C382
The pair cannot be created because the emulation type is not available for the specified volume.C388
The remote system is already used by Cnt Ac-S Z.C38B
The S-VOL is not available.C38D
The S-VOL is not supported by Cnt Ac-S Z.C38E
The S-VOL status is not Suspended or Suspended.C390
The S-VOL cannot be copied to because it is in the wrong pair status.C391
The volume cannot be used as an S-VOL because it is in online status, is already being used by Cnt Ac-S
Z, or is being used by another replication product.
C392
The S-VOL includes PIN data.C393
The S-VOL is in online status.C394
The S-VOL cannot be used due to LDEV blockage, collection access, or other reasons.C395
The pair cannot be created because the emulation type is not available for the specified volume.C398
An internal error occurred.C39B
The pair cannot be created because the capacity of the P-VOL exceeded the maximum volume capacity
allowed to create a Cnt Ac-S Z pair.
C39E
The pair cannot be created because the capacity of the S-VOL exceeded the maximum volume capacity
allowed to create a Cnt Ac-S Z pair.
C39F
The P-VOL is a device not supported by Cnt Ac-S Z.C3A0
The Cnt Ac-S Z pair cannot be added nor resumed because the specified data volume is in online status.C3A5
The SSID or CU number of the remote system is invalid.C3A6
The device type combination between the P-VOL and S-VOL is invalid.C3A8
The remote system’s cache is blocked on one side.C3AA
The remote system’s cache is blocked on one side.C3AB
Cnt Ac-S Z is not supported for this controller emulation type of the remote system.C3AC
Troubleshooting using RAID Manager 99