HP XP P9000 Continuous Access Synchronous for Mainframe Systems User Guide
DescriptionError code
(SSB2)
The pair operation was rejected because the online microcode is being replaced.B929
The pair cannot be created because the specified volume is a command device.B92A
The pair cannot be created because Cnt Ac-S Z is not installed.B934
S-VOL hide mode is not supported.B935
The specified volume is a P-VOL. The pair cannot be released because the P-VOL is specified as an S-VOL.B93B
The specified volume is an S-VOL. The pair cannot be released because the S-VOL is specified as an P-VOL.B941
The command was rejected because the volume status is Simplex.B945
The specified LU is not defined. The DKC configuration might have been changed. Restart RAID Manager.B952
The operation cannot run because pair status is Suspended, Suspended, or PDUB.B97B
The command was rejected because the volume status is Simplex.B97C
The pair cannot be created because the consistency group number is greater than is allowed.B990
If this error occurred when you did not specify the consistency group number, Contact HP for assistance.
The Swap Resync operation cannot be performed because the S-VOL is not in Suspended or SSWS status.
(Swap Resync resynchronizes differential data when the S-VOL is swapped for the P-VOL.)
B994
The pair cannot be created because the remote system path setting is invalid.B998
The pair cannot be created because Continuous Access Asynchronous is not supported.B99B
The DKC LDEV configuration might have been changed while starting RAID Manager. Restart RAID Manager.B9BD
The source of the command device has run out. In LUN Manager, set the command device to OFF, then to
ON.
B9C0
The pair cannot be suspended because the S-VOL and S-VOL were not paired with the specified serial
numbers and SSIDs.
C05E
A request for a Pairsplit-S operation was rejected because the S-VOL and S-VOL were not paired with the
specified serial numbers and SSIDs.
C073
A request for a Paircreate or Pairresync operation was rejected because the Cnt Ac-S Z program product
is not installed.
C075
The pair cannot be suspended because the S-VOL was not paired with the P-VOL.C0A1
A request for a Pairsplit-S operation was rejected because the S-VOL was not paired with the P-VOL using
the Paircreate command.
C0A2
The pair cannot be created because the specified DKC is the same for the P-VOL and S-VOL.C0F2
The pair cannot be resynchronized because the pair was not in the Suspend status.C162
The pair cannot be created because the S-VOL is not available.C16B
A request for a Pairsplit-S operation was rejected because the status change of the S-VOL failed.C184
A request for a Pairsplit-S operation was rejected because the pair status was invalid.C189
A request for a Pairsplit-S operation was rejected because the corresponding volume or group was changing
status.
C18A
The pair cannot be split because the S-VOL pair status was in transition.C194
A request for a Pairsplit-r operation was rejected because the pair status was already Suspended or
Suspended.
C195
Pair split cannot run because the group includes no pair that can be split.C198
Troubleshooting using RAID Manager 95