HP XP P9000 Continuous Access Synchronous for Mainframe Systems User Guide

Corrective actionDescriptionPath status
Repair the path relay equipment, then the path.
*
The path relay equipment
does not work.
Replace the broken cable, then restore the path.
*
The connection cable is
physically broken.
Restore the path.
*
A program error is detected.Program Error
Restore the path.
*
This path was not established.<blank>
* To restore a path, delete and then add the path again. It may be necessary to delete and then add the RCU again.
To delete the RCU or path, see “Deleting Continuous Access Synchronous Z” (page 86) or “Deleting logical paths
(page 81). To re-register, see “Configuring storage systems, defining logical paths” (page 58). If you cannot restore
the path after performing these operations, contact HP for assistance.
Suspended pairs problems
The following table provides a list of suspended pair types.
Corrective actionDescriptionApplies toPair status/type
Resynchronize the pair from the MCU (Resume
Pair).
The user suspended the pair from
the MCU using the P-VOL Failure
P-VOLP-VOL by
Operator
for Suspend Kind option. The
S-VOL suspend type is by MCU.
Resynchronize the pair from the MCU (Resume
Pair).
The user suspended the pair from
the MCU or RCU using the S-VOL
for Suspend Kind option.
P-VOL,
S-VOL
S-VOL by
Operator
Resynchronize the pair from the MCU (Resume
Pair).
The RCU received a request from
the MCU to suspend the pair. The
S-VOLby MCU
P-VOL suspend type is P-VOL by
Operator or S-VOL by Operator.
Clear the error condition at the remote system or
S-VOL, then resynchronize the pair from the main
system.
The main system detected an error
condition at the remote system,
which caused the main system to
P-VOL,
S-VOL
Suspended (pair
suspended-error)/
by RCU
If you need to access the S-VOL to clear the error
conditions, release the pair from the remote system.
suspend the pair. The S-VOL
suspend type is S-VOL Failure.
After you clear the error conditions from S-VOL,
restart the pair.
Release the pair from the MCU (Delete Pair), and
then restart the pair (Add Pair). You should use the
The MCU detected that the S-VOL
status changed to Simplex because
P-VOLDelete Pair to
RCU
Entire Volume initial copy option to resynchronizethe user released the pair from the
the pair. You can use the None initial copy option
only if no data on the P-VOL or S-VOL changed.
RCU. The pair cannot be
resynchronized because the S-VOL
does not have the Suspend status.
92 Troubleshooting