HP XP P9000 Continuous Access Synchronous for Mainframe Systems User Guide

Corrective actionDescriptionPath status
system are being used for
other connections.
systems, initiator ports for main systems. If necessary,
connect to the remote system to delete paths.
Reconfigure the ports, then add the paths and RCUs to the
MCU again.
The remote system's S/N
does not match the specified
S/N.
Serial Number
Mismatch
Make sure that you entered the correct remote system S/N
and Controller ID, and main and remote system port
numbers.
Make sure the main and remote system ports are configured
correctly.
Make sure that data path relay equipment is properly
configured and functional. This includes cables, connectors,
switches, extender devices, communication lines, and all
other devices connected to the extenders.
The specified port is not
configured as an initiator
Invalid Port Mode
Make sure the correct port on the main system is configured
as an initiator port.
port, or this path already
exists.
Make sure that no two paths between main and remote
system ports have the same settings.
Make sure that you entered the correct remote system S/N
and Controller ID, and main and remote system port
numbers.
Make sure that the main and remote system ports are
configured correctly.
Make sure that data path relay equipment is properly
configured and functional. This includes cables, connectors,
switches, extender devices, communication lines, and all
other devices connected to the extenders.
The specified port in the
remote system is physically
RCU Port Number
Mismatch
Make sure that you specified the correct remote system port
number. Correct the port number if necessary.
disconnected from the main
system.
Make sure that the cables between the main and remote
system ports and between the main and remote system
switches are connected correctly.
Make sure that the topology settings of the main and remote
system ports are correct.
Make sure that the remote system port is configured as an RCU
target port.
The specified remote system
port is not configured as an
RCU target port.
RCU Port Type
Mismatch
The main system connected
to the remote system
Communication Failed
Make sure that the remote system port and the relay
equipment are configured correctly.
successfully, but logical
Make sure that data path relay equipment is properly
configured and functional. This includes cables, connectors,
communication timeout
occurred.
switches, extender devices, communication lines, and all
other devices connected to the extenders.
Wait until processing is completed.Paths are being created or
deleted, or the port attribute
is being changed.
In Progress
See the following.Blockaded due to continual
path or link failure.
Logical Blockade
Repair the port on the main system, then restore the path.
*
The main system port does not
work.
Repair the port on the remote system, then restore the path.
*
The remote system port does
not work.
Secondary path status problems 91