HP XP P9000 Continuous Access Synchronous for Mainframe Systems User Guide
Secondary path status problems
The following table provides a list of secondary path status problems.
Corrective actionDescriptionPath status
None required.This path has been
successfully established and
Normal
can be used for Cnt Ac S Z
copy activities.
The link initialization
procedure to the remote
Initialization Failed
• Make sure that the main and remote systems are physically
and correctly connected.
system failed because the
• Make sure that you entered the correct remote system S/N,
Controller ID, and main and remote system port numbers.
physical path connection was
missing between the main
and remote system.
• Make sure the main and remote system ports are configured
correctly.
Communication between the
main and remote system
timed out.
Communication Time
Out
• Make sure the remote system is powered on and that NVS
and cache are fully functional.
• Make sure that network relay devices are properly
configured and functional. This includes cables, connectors,
switches, extender devices, communication lines, and all
other devices connected to the extenders.
The main system rejected the
logical path link control
Path Rejected
(MCU/RCU)
• Delete all paths and RCUs not in use.
• Make sure that all main and remote system ports are
properly configured: ordinary RCU target ports for remote
function because all logical
path resources in the main
90 Troubleshooting