HP XP P9000 Continuous Access Synchronous for Mainframe Systems User Guide
This is shown in the following table indicates the following:
• Italicized/Gray background: Cnt Ac-S and Cnt Ac-S Z pair status before the split operation
on the consistency group
• Regular font: Status after the split operation
Cnt Ac-S Z pairsPair statuses
All = SuspendSome = Duplex,
some = Suspend
All
Cnt Ac-S: PSUSCnt Ac-S: PSUSCnt Ac-S: PSUSAll = PAIR
Cnt Ac-S Z: SuspendCnt Ac-S Z: SuspendCnt Ac-S Z: Suspend
Cnt Ac-S: PSUSCnt Ac-S: PSUSCnt Ac-S: PSUSSome = PAIR,Cnt
Ac-S
Cnt Ac-S Z: SuspendCnt Ac-S Z: SuspendCnt Ac-S Z: Suspendsome = PSUS
Cnt
Ac-S
pairs
Cnt Ac-S: PSUSCnt Ac-S: PSUSCnt Ac-S: PSUSAll = PSUS
Cnt Ac-S Z: SuspendCnt Ac-S Z:Cnt Ac-S Z:
- RAID Manager:
Duplex/Suspend
- RAID Manager: Duplex
- BCM: Suspend
- BCM: Suspend
Error reporting communications
Error reporting communications (ERC) transfers information between host processors at the main
and remote sites. It is a critical component of a disaster recovery effort.
You can configure ERC using channel to channel communications, NetView technology, or other
inter-connection technologies depending on your installation requirements and standards. Cnt Ac-S
Z does not provide ERC between the main and remote sites.
• When Cnt Ac-S Z is used as a disaster recovery tool, ERC is required to ensure effective
recovery operations.
• When Cnt Ac-S Z is used as a data migration tool, ERC is recommended.
• When a pair is suspended due to an error condition, the main system generates sense
information that results in an IEA491E system console message. This information should be
transferred to the remote site using ERC for effective disaster detection and recovery.
Data path requirements and configurations
A data path must be designed to adequately manage all possible amounts of data that could be
generated by the host and sent to the P-VOL and S-VOL. This topic provides requirements and
planning considerations for the following key elements of the data path:
• “Bandwidth requirements” (page 46)
• “Fibre Channel requirements” (page 47)
• “Supported data path configurations” (page 47)
• “Ports” (page 49)
Bandwidth requirements
Sufficient bandwidth must be present to handle data transfer of all workload levels. The amount
of bandwidth required for your Cnt Ac-S Z system is based on the amount of I/O sent from the
host to the main volume. You determine required bandwidth by measuring write-workload. Workload
46 Planning for Continuous Access Synchronous Z