HP XP P9000 Continuous Access Synchronous for Mainframe Systems User Guide
DescriptionItem
Minimum number of paths for copy operations.Minimum Paths
Time in which the copy operation must complete or the operation fails. Range is from 10 to
100 seconds.
RIO MIH Time (sec.)
Support for the CGROUP (FREEZE/ RUN) PPRC TSO command. Enable or Disable.FREEZE Option
Time limit for data to travel from the P-VOL to the S-VOL.Round Trip Time (ms)
Add Path(Fibre) dialog box
Use this dialog box to configure additional logical paths.
See “Configuring additional logical paths” (page 62) for complete information.
168 GUI reference