HP XP P9000 Continuous Access Synchronous for Mainframe Systems User Guide
DescriptionItem
Time limit for data to travel from P-VOL to S-VOL.Round Trip Time
To refresh the RCU Operation window after closing the RCU Status dialog box, click the
check box. By default, the check box is not selected.
Check box, “Refresh the
RCU Operation window
after this dialog box is
closed”:
Add RCU (Fibre) dialog box
Use this dialog box to link two storage systems for Cnt Ac-S Z pairs.
See “Configuring storage systems, defining logical paths” (page 58) for complete information.
DescriptionItem
Remote storage system’s CU serial number.RCU S/N
Remote storage system’s LDKC number.LDKC
Remote storage system’s controller ID.Controller ID
Remote storage system’s CU number.Logical Adr. (RCU CU)
Remote storage system’s SSID.SSID
Path from the ports on the local and remote storage systems.MCU-RCU Path
RCU Option dialog box
Use this dialog box to change data path parameters: the minimum number of paths, RIO MIH,
FREEZE Option, and Round Trip Time options.
See “Configuring storage systems, defining logical paths” (page 58) for complete information.
Add RCU (Fibre) dialog box 167