HP XP P9000 Continuous Access Synchronous for Mainframe Systems User Guide

The Details for the arguments are:
P-VOL device list (numeric): L x 0x10000 + C x 0x100 + VV, where L=LDKC#, C=CU#,
VV=vol# within CU.
Serial number list (string): RCU serial number (serial number is five digits decimal 0-9). Do not
specify more than 12 RCUs.
SSID number list (numeric): RCU SSID (four digits hexadecimal).
S-VOL device list (numeric): L x 0x10000 + C x 0x100 + VV, where L=LDKC#, C=CU#,
VV=vol# within CU.
When you write P-VOL device list or S-VOL device list, you can omit LDKC# if the LDKC# is
0. For example, you can write 0x0102 when LDKC# is 0, CU# is 1, and vol# is 2.
Initial copy pace list (string): “CP_MIDDLE” = 3 tracks; “CP_FAST” = 15 tracks; default =
CP_FAST.Initial copy pace list (string): “CP_MIDDLE” = 3 tracks; “CP_FAST” = 15 tracks;
default = CP_FAST.
Initial copy mode list (string): “E” = entire volume; “N” = none; default = E.
Sync level list (string): “S0” or “Synchronous0”; default = S0.
Priority list (numeric): Priority of initial copy operation (1 -256); default = 32.
Fence level list (string): “N” or “Never” = never; “S” or “Status” = status; “D” or “Data” =
data; default = “Never”. For async pairs you must either specify N (never) or omit this
parameter.
CFW flag list (numeric): 0 = copy CFW data to S-VOL; 1 = only P-VOL; default = 1.
DFW flag list (numeric): 0 = DFW not required; 1 = DFW required; default = 0. Must be
omitted for async pairs.
Error level list (string): To maintain interchangeability with the script made with the model
before XP24000/XP20000 Disk Array, this parameter has been left. Do not use this parameter
with XP P9500.
Time-Saving Mode flag: “Yes” = The Use Time-Saving Mode option is enabled; “No” = The
Use Time-Saving Mode option is disabled; default = “Yes. This parameter is a non-list type
and only one value can be specified.
Differential management measurement flag list (string): The differential between the volumes
is managed in cylinder (“Cylinder” or “C”) or in track (“Track” or “T”). When “Auto” or “A
is specified, the storage system selects the differential management measurement (cylinder or
track) automatically. The default is Auto.
Time stamp transfer list (string): “Enable” = The host I/O time stamp is transferred from P-VOL
to S-VOL; “Disable” = The host I/O time stamp is not transferred from P-VOL to S-VOL; default
= “Disable. For the async pairs you must omit this parameter.
The CreateHrcPair . When using the CreateHrcPair command to create more than
one pair, make sure to keep each line within the maximum line length (320 bytes).
The following table shows parameters and example values.
ValueParameter
_ilDevAP-VOL
_slWorkASerial number (RCU)
11SSID (RCU)
_ilDevBS-VOL
_slWorkBInitial copy pace
EInitial copy mode
S0, S0, S0Sync level
Operation macro commands 133