HP XP P9000 Continuous Access Synchronous for Mainframe Systems User Guide
DescriptionError code
(SSB2)
The remote system capacity exceeds the license capacity.C3AD
Cnt Ac-S Z is not installed on the remote system.C3AE
The DKC type of the remote system is not supported by Cnt Ac-S Z.C3AF
The number of paths is smaller than the required minimum number of paths.C3B1
An internal error occurred.C3B3
The configuration combination of P-VOL and S-VOL is invalidC3B5
The P-VOL is an BC Z volume.C3B6
The S-VOL is an BC Z volume.C3B7
An internal error occurred.C3B8
The specified S-VOL LUN is not defined; or the LUN includes a CU LDEV that is not supported by the main
system.
C3B9
A request for an Add Pair operation was rejected because of one of the following reasons:C3BA
The remote system’s SSID or CU number is not supported.
Though the remote system’s SSID or CU number is supported, the microcode of the main system device does
not support them.
The P-VOL is in online status.C3BD
These volumes cannot be specified as a Cnt Ac-S Z S-VOLC3BE
BC Z T-VOL not in Suspended status
BC Z reserved volume
BC Z S-VOL in the process of reverse copy
A Cnt Ac-S Z S-VOL cannot be specified as an BC Z T-VOL, reserved volume, or S-VOL in the process of
reverse copy.
C3BF
When the S-VOL is the BC Z T-VOL, the BC Z volumes should be a one to one combination.C3C0
A request for an Add Pair operation was rejected because the specified volume was already part of a Cnt
Ac-S Z or Cnt Ac-J Z pair (including journal volumes).
C3C7
The S-VOL is reserved; or a remote system, S-VOL or the path between main system and remote system is
in the BUSY status.
C3CA
The S-VOL is an BC Z volume.C3CD
The DKC type of the remote system is not supported by Cnt Ac-S Z.C3D2
The SSID or CU number of the specified remote system is invalid.C3D3
A pair cannot be created because the P-VOL is being used by Auto LUN.C3D4
The specified S-VOL is unavailable because the connecting port cannot recognize it.C3D6
The pair status of the S-VOL is invalid.C3D7
The pair cannot be created because the volume specified for the S-VOL is a system volume.C3D8
The pair cannot be created if the Cnt Ac-S Z S-VOL corresponds to any of the following:C3D9
The volume is a THP V-VOL; the pair using the volume is a BC Z pair or a Auto LUN reserve volume.
The volume is a THP V-VOL and an addition to volume capacity is in progress, or pages are being released.
The capacity of the volume is different from the capacity of the P-VOL.
The volume is initialized by BC Z
The Cnt Ac-S Z pair cannot be created because the volume specified for the P-VOL is a system volume.C3DA
100 Troubleshooting